Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Type of study
Year range
1.
Rev. bras. oftalmol ; 69(1): 52-54, Jan,-Feb. 2010. ilus
Article in English | LILACS | ID: lil-549435

ABSTRACT

The authors report one case of orbital fracture of the floor and the medial walls after trauma with an intact ocular globe displacement into the maxillary sinus. The same authors emphasize the treatment, complications and the rarity of this case. In this case the patient developed a good visual acuity and a loss of ocular motility as complication (except abduction) .


Os autores relatam um caso de fratura de assoalho e parede medial de órbita após trauma com deslocamento de globo ocular intacto para o seio maxilar. Os mesmos autores enfatizam o tratamento, complicações e a raridade da entidade. Neste caso o paciente desenvolveu uma boa acuidade visual e uma perda de motilidade ocular como complicação (exceto abdução).


Subject(s)
Humans , Male , Adult , Orbital Fractures/complications , Maxillary Sinus , Tomography, X-Ray , Eye Injuries/complications , Visual Fields
2.
Arq. bras. oftalmol ; 72(4): 543-544, July-Aug. 2009. ilus
Article in English | LILACS | ID: lil-528024

ABSTRACT

The authors relate an uncommon case of pyogenic granuloma restricted to tarsal conjunctiva post retinopexy with scleral buckle.


Os autores relatam um caso de granuloma piogênico subconjuntival pós retinopexia com introflexão escleral. É uma complicação pós-cirúrgica incomum neste tipo de procedimento.


Subject(s)
Humans , Male , Middle Aged , Conjunctival Diseases/etiology , Granuloma, Pyogenic/etiology , Retinal Detachment/surgery , Scleral Buckling/adverse effects
3.
Rev. bras. oftalmol ; 68(4): 231-236, jul.-ago. 2009. tab, ilus
Article in Portuguese | LILACS | ID: lil-530971

ABSTRACT

Objetivo: Comparação da facilidade de aprendizado na realização da oftalmoscopia direta pelos alunos da graduação médica com o uso do oftalmoscópio convencional e do Panoptic. Métodos: Realizou- se um estudo comparativo da facilidade de aprendizado entre o uso do oftalmoscópio convencional e do panoptic para a realização do exame de fundo de olho de pacientes normais e com determinadas alterações específicas de fundo de olho. Foi usado para tal aferição um questionário formulado pelos autores e respondido pelos alunos da graduação na primeira e na oitava semana do curso. Resultados: Na primeira semana do curso, dos 60 alunos avaliados somente 1.60% tiveram maior facilidade de manipulação do aparelho com o panoptic, contrastando com 10.35% com o uso do convencional. Na oitava semana, 43.33% dos alunos demonstrou maior facilidade de manipulação com o uso do panoptic, contrastando com 17% com o uso do convencional. O teste estatístico de Kruskal Wallis se revelou de significância expressiva ( p < 0,05). Conclusão:: O oftalmoscópio de campo amplo (panoptic) necessita de um tempo de aprendizagem de uso um pouco maior em relação ao convencional, porém após este período facilita o aprendizado da oftalmoscopia direta por melhorar a observação das estruturas fundoscópicas.


Purpose: Comparison of the skill to teach the direct ophthalmoscopy class supported by fellows of medical graduation course using two examination methods: conventional ophthalmoscope and wide field ophthalmoscope (panoptic). Methods: Assessment of the competence to learn using a survey after eye fundus examination with conventional ophthalmoscope and wide field ophthalmoscope (panoptic). The group searched was composed of 60 students of university medical graduation course. The survey was applied during the first and eighth week of ophthalmogical class of medical graduation. The evaluation of competence to learning was token in as needing to help teachers to examination the eye fundus during the class, and the competence to manipulate the ophthalmoscopes. Tables and statical test (Kruskal Wallis) was performed to demonstrate the results analysis. Results: In the first week of ophthalmological class, only 1.60% of the students chose the panoptic ophthalmoscope, while the same score of 10.35% chosen with the conventional ophthalmoscope. In the eighth week of ophthalmological class the competence score with the panoptic ophthalmoscope raised to 43.33%, while conventional ophthalmoscope score stayed at 17%. The statistical analysis of Kruskal Wallis test revealed a positive significance (p< 0,05). Conclusion: The panoptic wide field ophthalmoscope needed a longer time to learn how to manipulate and observe the eye fundus, although after this time, the panoptic showed more competence and improved the eye fundus examination.


Subject(s)
Diagnostic Techniques, Ophthalmological , Education, Medical , Ophthalmoscopy/methods , Ophthalmoscopy , Surveys and Questionnaires
4.
Rev. bras. oftalmol ; 67(5): 247-249, set.-out. 2008. ilus
Article in Portuguese | LILACS | ID: lil-497330

ABSTRACT

Os autores relatam um caso de buraco macular por descarga elétrica, enfatizando que sua fisiopatologia difere das causas comuns, como a traumática e idiopática. Descrevem alterações morfológicas características utilizando a tomografia de coerência óptica (OCT) e imagens de retinografia.


The authors relate an uncommon case of macular hole following electric burn. They describe an uncommon physiopathology, which is different from traumatic and idiopathic macular hole.

5.
Rev. bras. oftalmol ; 67(4): 193-195, jul.-ago. 2008. ilus
Article in Portuguese | LILACS | ID: lil-492426

ABSTRACT

Os autores descrevem um caso de papilopatia diabética em paciente diabética insulino-dependente no qual se utilizou o acetonido de triancinolona com injeção intravítrea como opção de tratamento.


The authors describe one case of diabetic papillopathy. They used an intravitreal triamcinolone as an option of treatment.

6.
Rev. bras. oftalmol ; 67(1): 42-44, jan.-fev. 2008. ilus
Article in Portuguese | LILACS | ID: lil-482462

ABSTRACT

Os autores descrevem uma rara complicação de cirurgia de retinopexia com uso de fio de sutura de cerclagem de Arruga, evoluindo com erosão escleral e perfuração intra-ocular.


The authors relate an uncommon complication of retinopexy with encircling scleral buckle employing Arruga Suture, that has evolved to scleral erosion and intraocular damage.


Subject(s)
Humans , Female , Adult , Retinal Detachment/surgery , Sclera/injuries , Lasers, Gas/therapeutic use , Ophthalmologic Surgical Procedures/methods , Suture Techniques
SELECTION OF CITATIONS
SEARCH DETAIL